Johnson Controls Unitary Products 247585-UAI-F-0210
ACCESSORY KIT INSTALLATION INSTRUCTIONS
PROPANE CONVERSION - INDUCED COMBUSTION FURNACES – 1NP0347
FOR USE WITH 90% MODELS:
GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V,
FC9V, GM9V, TG9S, GG9S, TM9T, TM9V, TM9X, MG9S
FOR USE WITH 80% MODELS:
GY8S, GM8S, GR8S, PS8, FL8S, FC8S, PT8, FL8T, FC8T, GM8T, PV8, FL8V, FC8V, GM8V, LF8S, LY8S,
LM8S, LL8S, LC8S, LL8V, LC8V, LM8V, TG(8,L)S, GG(8,L)S, TM(8,L)T, TM(8,L)V, TM(8,L)X, YG8S
GENERAL
This kit is intended for the conversion of new equipment only,
from natural gas to propane gas operation.
All unit installations above 2,000 ft. (610 m) must be field
derated as required by the National Fuel Gas Code, ANSI
Z223.1 (latest edition), or in Canada, CAN/CGA B149.1 or .2
and all other applicable local codes and utility requirements.
This instruction covers the conversion of this unit when it is
equipped with a White-Rodgers gas valve. The installation
instruction supplied with the unit is to be used for all other
aspects of the installation.
This is a safety alert symbol. When you see this symbol
on labels or in manuals, be alert to the potential for per-
sonal injury.
Understand and pay particular attention to the signal words
DANGER, WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if
not avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if
not avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if
not avoided may result in minor or moderate injury
. It is also
used to alert against unsafe practices and hazards involving
only property damage.
This conversion kit shall be installed by a qualified service agency in accordance with these instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, an
explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified
service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation
of the converted appliance is checked as specified in these instructions supplied with the kit.
The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.
Installation must be made in accordance with American National Standard National Fuel Gas Code, ANSI Z223.1-latest edition,
unless superseded by local codes. For Canadian installations, the conversion shall be carried out in accordance with the require-
ments of the Provincial authorities having jurisdiction and in accordance with the CAN1-B149.1 and .2 installation codes.
The manufacturer accepts no responsibility for malfunctions due to improper conversions
Lo-NOx furnaces requiring propane (LP) gas must have the NOx screens removed prior to operation. Failure to do so may result
in operational problems and/or reduced heat exchanger life. Follow the instructions below for removal of the NOx screens.
For the 130,000 BTU, 33” series only: Use a #56 orifice pro-
pane Kit S1-1NP0501 is needed.
Improper installation, adjustment, service or maintenance
can cause injury or property damage; therefore, only a qual-
ified installer or qualified service personnel should perform
this conversion.
These instructions are for the use of qualified individuals
specially trained, experienced and certified in the installation
of this type of equipment and related systems components.
Installation and service personnel are required by some
states to be licensed. Persons not qualified shall not install
this equipment nor interpret these instructions.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - FOR USE WITH 80% MODELS:

Johnson Controls Unitary Products 247585-UAI-F-0210ACCESSORY KIT INSTALLATION INSTRUCTIONSPROPANE CONVERSION - INDUCED COMBUSTION FURNACES – 1NP0347FO

Page 2 - FURNACE CONVERSION

247585-UAI-F-02102 Johnson Controls Unitary ProductsFURNACE CONVERSION1. Shut off gas supply at shutoff valve upstream of the furnaceor at meter as re

Page 3

247585-UAI-F-0210Johnson Controls Unitary Products 3NOX SCREEN REMOVAL (Lo-NOx 80% Models Only)1. Make sure that the electrical power to the unit is t

Page 4 - INLET GAS PRESSURE RANGE

247585-UAI-F-02104 Johnson Controls Unitary ProductsReading the gas pressure with the burner box cover removed - Remove the screws securing the burner

Page 5 - (40” MODELS)

247585-UAI-F-0210Johnson Controls Unitary Products 5TWO STAGE GAS VALVE MODELS (40” MODELS)1. Refer to Figure 2 for location of pressure regulator adj

Page 6 - (PROPANE GAS)

247585-UAI-F-02106 Johnson Controls Unitary ProductsCALCULATING THE FURNACE INPUT(NATURAL GAS)1. Turn off all other gas appliances connected to the ga

Page 7

247585-UAI-F-0210Johnson Controls Unitary Products 7In the USA use the following formula to calculate the furnace input.For natural gas multiply the h

Page 8

Subject to change without notice. Published in U.S.A. 247585-UAI-F-0210Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 247